UC IPM Online UC ANR home page UC IPM home page

UC IPM Home

SKIP navigation

 

How to Manage Pests

California Weather Data

Description of WOODBRIDGE-01.P (WOD)

PestCast Network(s)

San Joaquin WEATHERNET

Observer

JOE GRANT

Location

Near Peltier Road and I-5
County: San Joaquin
Latitude: 38 deg 10 min N    Longitude: 121 deg 20 min W    Elevation: 46 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Grape

Available data

UC IPM database records begin/end: January 12, 1998  /  on-going
Reporting interval: Hourly, Daily
Stored variables:
Air Temperature, max/min: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Air Temperature 2, max/min: HMP35C-U temp-RH probe
Air Temperature, average: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Air Temperature 2, average: HMP35C-U temp-RH probe
Chilling Hours: hours T < 45F
Dew Point Temperature: calculated from HMP35C temp-RH probe
Evapotranspiration: Calculated Reference Evapotranspiration
Precipitation: TE525-L25 tipping bucket rain guage
Relative Humidity, average: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Solar Radiation: LI200X Silicon pyranometer
Temperature Threshold Hours: hours of T <= 32F; 70 <= T <= 85F; T > 95F
Wind Speed/Direction, average: 3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, maximum: 3001 RM Young Wind Sentry Anemometer and Vane
Variables with computed averages: none

Comments

Near a grape vineyard. NOTE: Disregard Solar Radiation readings fom 6/25/98 through 5/13/99.


Details about reported variables

Air Temperature, max/min
Variable or Sensor: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 10 April 1997
Backup Station #1 / #2 LODI-01.P   /  LODI_WEST.A
Averages Station Backup: LODI.C
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily
Air Temperature 2, max/min
Variable or Sensor: HMP35C-U temp-RH probe
Height of Sensor: 1.5 m (4.92 ft)
Sensor Setup: in grape canopy
When Installed: 10 April 1997
Backup Station #1 / #2 LODI-01.P   /  LODI_WEST.A
Averages Station Backup: LODI.C
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Air Temperature, average
Variable or Sensor: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Air Temperature 2, average
Variable or Sensor: HMP35C-U temp-RH probe
Height of Sensor: 1.5 m (4.92 ft)
Sensor Setup: in grape canopy
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Chilling Hours
Variable or Sensor: hours T < 45F
When Installed: 30 January 1998
Reporting Intervals: Daily
Dew Point Temperature
Variable or Sensor: calculated from HMP35C temp-RH probe
When Installed: 30 January 1998
Reporting Intervals: Hourly, Daily
Evapotranspiration
Variable or Sensor: Calculated Reference Evapotranspiration
Sensor Setup: calculated
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Precipitation
Variable or Sensor: TE525-L25 tipping bucket rain guage
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Relative Humidity, average
Variable or Sensor: HMP35C-U temp-RH probe at 1.5 m (4.92 ft)
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Solar Radiation
Variable or Sensor: LI200X Silicon pyranometer
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Temperature Threshold Hours
Variable or Sensor: hours of T <= 32F; 70 <= T <= 85F; T > 95F
When Installed: 30 January 1998
Reporting Intervals: Daily
Wind Speed/Direction, average
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly
Wind Speed/Direction, maximum
Variable or Sensor: 3001 RM Young Wind Sentry Anemometer and Vane
When Installed: 10 April 1997
Comment: Location is surrounded by grape vineyards.
Reporting Intervals: Daily, Hourly

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: September 2, 2014 Contact webmaster.