Description of Prunedale_South-01.P (PRUN)

PestCast Network(s)

Coastal Strawberry

Observer

Mike Oliver, Pacific Gold Farms

Location

Along Blackie Road near Highway 101
County: Monterey    Nearest City: Prunedale
Latitude: 36 deg 46 min N    Longitude: 121 deg 39 min W

Station and site characteristics

Manufacturer/model: Campbell Scientific CR10X
Crop: Strawberries

Available data

UC IPM database records begin/end: January 25, 2003  /  September 18, 2003
Reporting interval: 15 minute, Hourly, Daily
Stored variables:
Air Temperature, max/min: HMP45C-U temp-RH probe
Air Temperature 2, max/min: HMP45C-U temp-RH probe
Air Temperature, average: HMP45C-U temp-RH probe
Air Temperature 2, average: HMP45C-U temp-RH probe
Chilling Hours: hours T < 45F
Dew Point Temperature: calculated from HMP45C-U temp-RH probe
Leaf wetness: 237 resistance grid
Precipitation: TE525-L25 tipping bucket rain guage
Relative Humidity, average: HMP45C-U temp-RH probe
Variables with computed averages: none

Comments

Station Code: PRUN


Details about reported variables

Air Temperature, max/min
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: within strawberry canopy
When Installed: 24 January 2003
Backup Station #1 SALINAS.A
Averages Station Backup: SALINAS.A
Reporting Intervals: Daily, Hourly, 15 minute
Air Temperature 2, max/min
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: in strawberry canopy
When Installed: 24 January 2003
Reporting Intervals: Hourly
Air Temperature, average
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: within strawberry canopy
When Installed: 24 January 2003
Comment: Note: units for 15 minute data is degrees Fahrenheit
Reporting Intervals: Daily, Hourly, 15 minute
Air Temperature 2, average
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: in strawberry canopy
When Installed: 24 January 2003
Reporting Intervals: Hourly, 15 minute
Chilling Hours
Variable or Sensor: hours T < 45F
When Installed: 24 January 2003
Reporting Intervals: Daily
Dew Point Temperature
Variable or Sensor: calculated from HMP45C-U temp-RH probe
Sensor Setup: within strawberry canopy
When Installed: 24 January 2003
Reporting Intervals: Hourly
Leaf wetness
Variable or Sensor: 237 resistance grid
Height of Sensor: plant height
Sensor Setup: in strawberry canopy
When Installed: 24 January 2003
Comment: Units for daily leaf wetness are hours of wetness.
Reporting Intervals: Daily, Hourly, 15 minute
Precipitation
Variable or Sensor: TE525-L25 tipping bucket rain guage
Sensor Setup: above stawberry canopy
When Installed: 24 January 2003
Comment: Hourly precip is actually a running daily accumulation amount.
Reporting Intervals: Daily, Hourly
Relative Humidity, average
Variable or Sensor: HMP45C-U temp-RH probe
Sensor Setup: in strawberry canopy
When Installed: 24 January 2003
Reporting Intervals: Daily, Hourly, 15 minute

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: July 12, 2014 Contact webmaster.