Station and site characteristics
Manufacturer/model: Campbell Scientific CR10 or CR10X
Ground cover: Irrigated Turf,
Soil type: Sandy loam
Available data
UC IPM database records begin/end: September 19, 2007
/ period
Reporting interval: Daily
Stored variables:
Air Temperature, max/min:
Daily max/min measured at 1.5 m (4.92 ft).
Evapotranspiration:
Calculated from CIMIS hourly values.
Precipitation:
Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min:
Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min:
Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation:
Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction, average:
Daily average measured at 2 m (6.5 ft).
Variables with computed averages: none
Comments
Station equipment relocated from Station 176 sits. Site is on a Golf Course near the clubhouse. ETo reporting location with good clearance for rain gauge. Precip will be reported.
Details about reported variables
Air Temperature, max/min
| Variable or Sensor: |
Daily max/min measured at 1.5 m (4.92 ft). |
| Height of Sensor: |
1.5 m (4.92 ft) |
| When Installed: |
06 February 2007 |
| Status: |
Active |
| Backup Station #1
/ #2
| Indio_2.A / OASIS.A |
| Averages Station Backup: |
INDIO.C |
94% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Evapotranspiration
| Variable or Sensor: |
Calculated from CIMIS hourly values. |
| When Installed: |
06 February 2007 |
| Status: |
Active |
100% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Precipitation
| Variable or Sensor: |
Daily total measured in a 20 cm (8 in) diameter gauge. |
| Height of Sensor: |
2.4 meters |
| When Installed: |
06 February 2007 |
| Status: |
Active |
| Backup Station #1
/ #2
| OASIS.A / INDIO.C |
| Averages Station Backup: |
INDIO.C |
100% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Relative Humidity, max/min
| Variable or Sensor: |
Daily max/min relative humidity measured at 1.5 m (4.92 ft). |
| Height of Sensor: |
1.5 m (4.92 ft) |
| When Installed: |
10 November 2000 |
| Status: |
Active |
94% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Soil Temperature, max/min
| Variable or Sensor: |
Daily max/min measured at a 15 cm (6 in) depth. |
| Height of Sensor: |
15 cm (6 in) depth |
| When Installed: |
06 February 2007 |
| Status: |
Active |
| Backup Station #1
/ #2
| INDIO.A / OASIS.A |
| Averages Station Backup: |
THERMAL.A |
99% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Solar Radiation
| Variable or Sensor: |
Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft). |
| Height of Sensor: |
2 m (6.5 ft) |
| When Installed: |
06 February 2007 |
| Status: |
Active |
| Backup Station #1
/ #2
| INDIO.A / OASIS.A |
| Averages Station Backup: |
THERMAL.A |
97% of possible values are stored for the period
09/19/2007 to 06/15/2013.
Wind Speed/Direction, average
| Variable or Sensor: |
Daily average measured at 2 m (6.5 ft). |
| Height of Sensor: |
2 m (6.5 ft) |
| When Installed: |
06 February 2007 |
| Status: |
Active |
96% of possible values are stored for the period
09/19/2007 to 06/15/2013.