Description of GONZALES.A (CIMIS #115, Gonzales)

Network:

CIMIS — California Irrigation Management Information System

Observer

MONTEREY COUNTY WATER RESOURCES AGENCY - DWR SAN JOAQUIN DISTRICT

Location

County: Monterey    Nearest City: Gonzales
Latitude: 36 deg 31 min N    Longitude: 121 deg 31 min W    Elevation: 146 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Ground cover: Irrigated grass

Available data

UC IPM database records begin/end: June 18, 1993  /  November 9, 1998
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Reference Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction: Daily average measured at 2 m (6.5 ft).
Variables with computed averages: none


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
Backup Station #1 / #2 SALINAS.A   /  SALINAS.C
Averages Station Backup: SALINAS.C

99% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Reference Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Backup Station #1 / #2 SALINAS.A   /  SALINAS.C
Averages Station Backup: SALINAS.C

99% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Relative Humidity, max/min
Variable or Sensor: Daily max/min relative humidity measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)

100% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
Backup Station #1 SALINAS.A
Averages Station Backup: SALINAS.A

95% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
Backup Station #1 SALINAS.A
Averages Station Backup: SALINAS.A

99% of possible values are stored for the period 06/18/1993 to 11/09/1998.

Wind Speed/Direction
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)

100% of possible values are stored for the period 06/18/1993 to 11/09/1998.