|
|
How to Manage Pests
Description of ESCALON-01.P
(ESL)
|
PestCast Network(s)San Joaquin WEATHERNET
Observer
JOE GRANT
Location
Near River Road and McHenry Avenue
County: San Joaquin
Latitude: 37 deg
46 min N
Longitude: 120 deg
59 min W
Elevation: 115 ft
Station and site characteristics
Manufacturer/model: Campbell Scientific Inc. CR-10 ( or CR-10X)
Crop: Almonds
Ground cover: Almond orchard
Available data
UC IPM database records begin/end: January 10, 1998
/ on-going
Reporting interval: Hourly, Daily
Stored variables:
Air Temperature, max/min:
HMP35C-U temp-RH probe
Air Temperature, average:
HMP35C-U temp-RH probe
Chilling Hours:
hours T < 45F
Evapotranspiration:
Calculated Reference Evapotranspiration
Leaf wetness:
237 Wetness sensing grid
Precipitation:
TE525-L25 tipping bucket rain guage
Relative Humidity, average:
HMP35C-U temp-RH probe
Solar Radiation:
LI200X Silicon pyranometer
Temperature Threshold Hours:
hours of T <= 32F; 70 <= T <= 85F; T > 95F
Wind Speed/Direction, average:
3001 RM Young Wind Sentry Anemometer and Vane
Wind Speed/Direction, maximum:
3001 RM Young Wind Sentry Anemometer and Vane
Variables with computed averages: none
Comments
Within an almond orchard
Details about reported variables
Air Temperature, max/min
| Variable or Sensor: |
HMP35C-U temp-RH probe |
| Sensor Setup: |
edge of an almond orchard |
| When Installed: |
10 April 1997 |
| Backup Station #1
/ #2
| FARMINGTON-01.P / MANTECA.A |
| Averages Station Backup: |
MANTECA.A |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily |
Air Temperature, average
| Variable or Sensor: |
HMP35C-U temp-RH probe |
| Sensor Setup: |
edge of an almond orchard |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Chilling Hours
| Variable or Sensor: |
hours T < 45F |
| When Installed: |
30 January 1998 |
| Reporting Intervals: |
Daily |
Evapotranspiration
| Variable or Sensor: |
Calculated Reference Evapotranspiration |
| Sensor Setup: |
calculated |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Leaf wetness
| Variable or Sensor: |
237 Wetness sensing grid |
| Height of Sensor: |
plant height |
| Sensor Setup: |
Inside the canopy with no other significant obstructions. |
| When Installed: |
01 April 1998 |
| Reporting Intervals: |
Daily, Hourly |
Precipitation
| Variable or Sensor: |
TE525-L25 tipping bucket rain guage |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Relative Humidity, average
| Variable or Sensor: |
HMP35C-U temp-RH probe |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Solar Radiation
| Variable or Sensor: |
LI200X Silicon pyranometer |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Temperature Threshold Hours
| Variable or Sensor: |
hours of T <= 32F; 70 <= T <= 85F; T > 95F |
| When Installed: |
30 January 1998 |
| Reporting Intervals: |
Daily |
Wind Speed/Direction, average
| Variable or Sensor: |
3001 RM Young Wind Sentry Anemometer and Vane |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Wind Speed/Direction, maximum
| Variable or Sensor: |
3001 RM Young Wind Sentry Anemometer and Vane |
| When Installed: |
10 April 1997 |
| Comment: |
Located at edge of an almond orchard. |
| Reporting Intervals: |
Daily, Hourly |
Top of page
|