UC IPM Online UC ANR home page UC IPM home page

UC IPM Home

SKIP navigation

 

How to Manage Pests

California Weather Data: Station Description

Description of ATASCADERO.A (CIMIS #163, Atascadero)

Network:

CIMIS — California Irrigation Management Information System

Observer

Atascadero Mutual Water Company

Location

Chalk Mountain Golf Course
County: San Luis Obispo    Nearest City: Atscadero
Latitude: 35 deg 28 min N    Longitude: 120 deg 39 min W    Elevation: 885 ft

Station and site characteristics

Manufacturer/model: Campbell Scientific CR10 or CR10X
Ground cover: Irrigated Turf, Soil type: Clay Loam

Available data

UC IPM database records begin/end: November 24, 2000  /  on-going
Reporting interval: Daily
Stored variables:
Air Temperature, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Evapotranspiration: Calculated from CIMIS hourly values.
Precipitation: Daily total measured in a 20 cm (8 in) diameter gauge.
Relative Humidity, max/min: Daily max/min measured at 1.5 m (4.92 ft).
Soil Temperature, max/min: Daily max/min measured at a 15 cm (6 in) depth.
Solar Radiation: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Wind Speed/Direction, average: Daily average measured at 2 m (6.5 ft).

Comments

Rain gauge is currently subject to being hit by sprinkler irrigation. Rain gauge datatype may be turned off until has been moved.


Details about reported variables

Air Temperature, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 24 November 2000
Status: Active
Backup Station #1 SNLUIS_O.A
Averages Station Backup: PASOROBL.C

90% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Evapotranspiration
Variable or Sensor: Calculated from CIMIS hourly values.

100% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Precipitation
Variable or Sensor: Daily total measured in a 20 cm (8 in) diameter gauge.
Height of Sensor: 1 m (39 in)
When Installed: 24 November 2000
Status: INACTIVE
Backup Station #1 SNLUIS_O.A
Averages Station Backup: PASOROBL.C

98% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Relative Humidity, max/min
Variable or Sensor: Daily max/min measured at 1.5 m (4.92 ft).
Height of Sensor: 1.5 m (4.92 ft)
When Installed: 24 November 2000
Status: Active

91% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Soil Temperature, max/min
Variable or Sensor: Daily max/min measured at a 15 cm (6 in) depth.
Height of Sensor: 15 cm (6 in) depth
When Installed: 24 November 2000
Status: Active
Backup Station #1 SNLUIS_O.A
Averages Station Backup: SNLUIS_O.A

96% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Solar Radiation
Variable or Sensor: Daily global radiation measured by Licor pyranometer at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 24 November 2000
Status: Active
Backup Station #1 SNLUIS_O.A
Averages Station Backup: SNLUIS_O.A

95% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Wind Speed/Direction, average
Variable or Sensor: Daily average measured at 2 m (6.5 ft).
Height of Sensor: 2 m (6.5 ft)
When Installed: 24 November 2000
Status: Active

99% of possible values are stored for the period 11/24/2000 to 11/20/2014.

Top of page


Statewide IPM Program, Agriculture and Natural Resources, University of California
All contents copyright 2014 The Regents of the University of California. All rights reserved.

For noncommercial purposes only, any Web site may link directly to this page. FOR ALL OTHER USES or more information, read Legal Notices. Unfortunately, we cannot provide individual solutions to specific pest problems. See our Home page, or in the U.S., contact your local Cooperative Extension office for assistance.

Agriculture and Natural Resources, University of California

Accessibility   web template revised: November 24, 2014 Contact webmaster.